The
type 6244 is designed as a fully automatic pressurising
dehydrator unit. Routine maintenance is minimised
by the use of an automatically regenerated molecular
sieve. Scheduled maintenance intervals are only
required after 5000 hours of compressor run time,
with a typical duty cycle of 5% - 10% this unit
is capable of running for prolonged periods without
intervention. The standard unit is fitted with
an air receiver tank in series with the dry air
output, the pressure in this tank is sensed by
the control electronics, closed loop control of
the compressor ensures that this pressure is maintained
at a preset level. This design feature ensures
that the dry air output pressure remains stable
over a range of load conditions, it also serves
to minimise the compressor duty cycle.
COMPRESSOR
Oil-less Air Compressor
POWER SUPPLY
415 Volts, 50 Hz, 2.2 KW, 10A
DRY AIR OUTPUT
Minimum 150 Ltrs per min
OUTPUT PRESSURE
0-15 psi adjustable through
distribution panel
(available from Cable Pressure Systems).
DEWPOINT
Better than -40 Degrees Celsius
in ambient conditions
of +30 Degrees Celsius and 75% RH
WET DRY BYPASS
Fail safe solenoid valve at
dry air inlet to air receiver.
GAUGES
Compressor Running Pressure
Air Receiver Pressure
Dewpoint Trend (Digital Readout)